Trust Guard Security Scanned
hours left for
same day shipping
hours left for
same day shipping

⚠️ Shipping Times May Vary Based on Inclement Weather Conditions

Loading...

Febco 765 PVB Backflow Preventer 1-1/4 in. FPT | FE765-125

SKU
FE765-125
Free Shipping on Orders over $149
Sales Price $548.53 Our Price $1,395.95 You save 61%

Febco 765 1-1/4 in. PVB Backflow Preventer

FEBCO Series 765 Pressure Vacuum Breakers are designed to be installed to provide protection against back siphonage of toxic or non-toxic liquids. They feature a durable bronze body and a check valve and air opening port in one assembly.

Features & Benefits
  • All bronze body for durability. One check valve and an air opening port in one assembly.
  • Lightweight poppet seals air opening under minimum flow conditions.
  • Simple service procedures. All internal parts serviceable in line from the top of the unit.
  • Designed for minimum head loss.
  • Engineered plastic bonnet protect valve bodies from freeze damage.
  • End Connections - NPT ANSI/ASME B1.20.1
  • Maximum Working Pressure: 150psi.
Specifications

Pressure Vacuum Breaker assemblies shall be in stalled to withstand pressure for long periods and to prevent backflow of contaminated water into the potable water system in backsiphonage conditions. The Pressure Vacuum Breaker assembly shall consist of a single spring loaded check valve which closes tightly when water flow through the assembly drops to zero, and a single air relief valve that opens to break the siphon when pressure drops to 1psi.

The assembly shall include two resilient seated shut-offs and two resilient seated test cocks, considered integral to the assembly. Assemblies must be factory backflow tested. The check valve and air inlet valve must be constructed to allow in-line servicing of the assembly. The valve body shall be constructed of bronze. The check, poppet and bonnet assembly shall be constructed of engineered plastic to protect the valve body from freeze damage. Pressure Vacuum Breaker assemblies shall be installed a minimum of 12" (300mm) above the highest downstream outlet, and the highest point in the downstream piping.

The assembly shall be rated to 150psi working pressure and water temperature from 32 degrees F to 140 degrees F. The assembly shall meet the specifications of the USC - FCCC & HR Manual. Pressure Vacuum Breaker assemblies shall be FEBCO? Series 765 or prior approved equal.

Materials
  • Main Valve Body: Bronze
  • Elastomers: Nitrile

WARNING! Irrigation systems supplied by domestic or private potable water systems are considered to be a potential pollution hazard to the water supply. These systems must include protection to prevent possible backflow of irrigation water into the potable water supply.

Federal law requires a proper backflow device to be installed on any watering system to prevent contamination of the supply; whether it be pump or city water. Check your local water authority for installation requirements & codes. In many rural areas; specific requirements for landscape irrigation systems may not be covered in local plumbing codes and/or enforcement may be limited. HOWEVER...limitation in local authority does not alter the basic requirement for protection of the potable water supply.

*Red indicates repair parts sold at the Sprinkler Warehouse

More Information
Brand Febco
Test Cocks 2 FEMALE
Max Working Pressure 150 PSI
Hydrostatic Test Pressure 300 PSI
Temperature Range 32F to 140F
Main Valve Body Materials Bronze
Elastomers Nitrile
Springs Stainless Steel
Warranty 1 Year
Size 1-1/4 in.
Connection FPT
Lead Free Not Lead Free
Specifications (88.65 kB)