View Cart Checkout
 

Order within 0hrs 0mins for same-day shipping!
*Not available with backorder/drop-ship items. See Shipping Policy



  Home > Backflow Preventers > Double Check Valves > Wilkins Double Check Valves >

  Wilkins 350BOF-200 2 in. DCA With Blow Out Flush Fitting
Wilkins 350BOF 2 in. DCA With Blow Out Flush Fitting
 



Our Price: $396.95


Product Code: WK350BOF-200
Qty:

Description
 
Wilkins WK350BOF-200 2 inch Double Check with Blow-Out Flush Fitting
Wilkins WK350BOF-200 2 inch Double Check with Blow-Out Flush Fitting


Product Manuals
Specifications
Instructions
360 Degree Product View
Not Available
Product Videos
Not Available
Performance Charts
Not Available
Product Information

WILKINS WK350BOF-200 2 INCH DOUBLE CHECK VALVE ASSEMBLY WITH BLOW-OUT / FLUSH FITTING:

Designed for installation on water lines to protect against both backsiphonage and backpressure of polluted water into the water supply. Assembly shall provide protection where a potential health hazard does not exists.

Features & Benefits
  • Maximum working water pressure: 175 PSI
  • Maximum working water temperature: 180° F
  • Hydrostatic test pressure: 350 PSI
  • End connections Threaded: ANSI B1.20.1
Materials
  • Main valve body: Cast Bronze, ASTM B 584 (3/4-1")
  • Housing: Reinforced Nylon
  • Fasteners: Stainless Steel, 300 Series
  • Elastomers:
    • Silicone (FDA Approved)
    • Buna Nitrile (FDA Approved)
  • Internals: Delrin, NSF Listed
  • Springs: Stainless Steel, 300 series
  • Ball Valves: Cast Bronze, ASTM B 584
  • Struts: Forged Brass ASTM B 124
Wilkins 350 Series Double Check Assembly Diagram
Specifications
The Double Check Valve Backflow Preventer shall be ASSE® Listed 1015, rated to 180°F and supplied with full port ball valves. The main body shall be Bronze for sizes 3/4" & 1", and Nylon for sizes 1-1/4" to 2". The housing shall be reinforced Nylon and the seat disc elastomers shall be silicone (FDA Approved). The first and second checks shall be accessible for maintenance without removing the device from the line. The Double Check Valve Backflow Preventer shall be a WILKINS Model 350.
Standards Compliance (Horizontal & Vertical)
  • ASSE® Listed 1015
  • IAPMO® Listed
  • CSA® Certified B64.5
  • Approved by the Foundation for Cross Connection
    Control and Hydraulic Research at the University of Southern California
  • UL® Classified (less shut-off valves only)
  • C-UL® Classified (less shut-off valves only)
Wilkins 350 Series Double Check Assembly Capacity
Wilkins 350 Series Double Check Assembly Dimensions
Wilkins 350 Series Double Check Assembly Flow Characteristics
Typical Installation
Local codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. If installed below grade, be certain adequate drainage is provided to prevent the device from being submerged.

Wilkins WK350FT-200 2 in. DCA With SAE Male Test Cock




Browse for more products in the same category as this item:

Backflow Preventers > Double Check Valves > Wilkins Double Check Valves
Wilkins
 
   
  .