What Type Of Backflow Devices Are Available?

Types of Backflow Preventers

Overview of Four Common Backflow Preventers

Back Button

There are multiple types of backflow preventers, the three most common being the pressure vacuum breaker (PVB), the reduced pressure zone (RPZ), and the double check assembly (DCA). These are all installed in the water system immediately after the isolation valve. There is a fourth backflow preventer which is also fairly common; the atmospheric vacuum breaker (AVB), which is installed on each zone of the sprinkler system, immediately after the zone control valve. Each type of backflow device is designed to provide a different level of protection for varying commercial or residential applications. For example, hospitals and morgues, which handle large quantities of hazardous wastes on a daily basis, require much heavier-duty backflow preventers than a residential irrigation system.

Several factors must be taken into consideration when selecting a backflow device, including local building codes regulating backflow preventers, the size of the landscape to be irrigated, and where the backflow preventer is going to be installed. It's a good idea to familiarize yourself with the different types of backflow devices, and select the one that best meets your requirements.

Pressure Vacuum Breaker

Pressure vacuum breaker assemblies (PVB) are the most common, inexpensive type of whole-system backflow preventer. It consists of an inlet shutoff valve at the bottom, a single valve body consisting of a pressure vacuum breaker, check valve, and two test cocks, and an outlet shutoff valve. As well as being inexpensive, PVBs are relatively simple in design, and are easy to install, maintain and repair. Some pressure vacuum breakers also offer built-in freeze protection; however, this only protects the PVB assembly. Inlet and outlet pipes can still freeze if the system isn’t properly winterized.

One of the downsides of PVBs is that they will occasionally eject some water. Choose a "spill-resistant" model of PVB for indoor installations or any time spillage would create a nuisance. An air gap drain is also required if the valve is installed in a basement or other interior space.

Pressure Vacuum Breaker Assemblies:

  • Must be installed at least twelve inches above the highest downstream point on the system
  • Must be installed vertically (with the inlet at the bottom)
  • Prevents back-siphonage only, not back-pressure
  • No chemigation with PVBs
  • Installation not allowed where back-pressure is a potential threat

Popular Major Brands:

Shop Febco Vacuum Breaker Assemlies. Shop Conbraco Vacuum Breaker Assemlies. Shop Wilkins Vacuum Breaker Assemlies.

Double Check Valves


Double check valves (DCV, also called double check assemblies or DCA) are a good choice for underground or indoor installations. A DCA consists of an inlet shutoff valve, two independently operating spring-loaded check valves (usually inside a single valve body), four test cocks, and an outlet shutoff valve. Double check assemblies should only be installed vertically if allowed by local building codes.

Backflow Prevention Devices: Double Check Valve Assembly

The DCA is the most common type of approved backflow prevention device for use in underground or in-line installations. In-line (or below-grade) simply means that the backflow device is parallel with the piping of the sprinkler system; unlike the PVB, the DCA does not have to be installed 12 inches above the highest point in the system. Some areas do require above-ground installation, so check with local authorities before installing below ground.

It is possible to build a double check valve assembly from new components, but this is not the best option as there is a high risk of built assemblies not meeting local code. A better option, for convenience, cost-effectiveness, and coding restrictions, is to purchase a pre-assembled double check valve assembly.

Double Check Valve Assemblies:

    May be installed either above ground or inline (underground) May not be used with chemigation May be installed horizontally or vertically, but horizontally is preferred May be installed where the potential for back-siphonage or backpressure is present

Popular Major Brands:

Shop Febco Double Check Valve Assemlies. Shop Conbraco Double Check Valve Assemlies. Shop Wilkins Double Check Valve Assemlies.

Reduced Pressure Zone Assembly


Reduced pressure zone assemblies (RPZ), also sometimes called a reduced pressure principle assembly, is the most complex and expensive backflow preventer. However, when working properly, RPZs are the most secure and reliable of all backflow prevention devices. A reduced pressure zone assembly consists of an inlet shutoff valve, two independently operating spring-loaded check valves separated by a pressure differential relief valve, four test cocks, and an outlet shutoff valve.

Backflow Prevention Devices: Reduced Pressure Zone Assembly

Some localities, such as Honolulu, do not allow reduced pressure zone assemblies to be installed below grade in underground lawn sprinkler systems, while others require copper pipe on both ends of the assembly. Local codes may be especially variable and stringent on reduced pressure zone assembly, so have a thorough understanding of local requirements before proceeding.

Reduced pressure zone assemblies come in a variety of configurations. Choose an "inline" or "straight" configuration for installation underground. For above-ground installation, consider an "n" configuration assembly for a very small footprint.

Reduced Pressure Zone Assemblies:

  • Compatible with both aboveground or belowground installation, aboveground preferred
  • Chemigation is approved with RPZs
  • Horizontal installation required unless factory-configured for alternate installation
  • Protects against both beck-siphonage and back-pressure

Popular Major Brands:

Shop Febco Reduced Pressure Zone Assemlies. Shop Conbraco Reduced Pressure Zone Assemlies. Shop Wilkins Reduced Pressure Zone Assemlies.

Atmospheric Vacuum Breaker (Anti-Siphon)


Backflow Prevention Devices: Atmospheric Vacuum Breaker (Anti-Siphon)

Atmospheric vacuum breakers (AVB) are the simplest and least expensive backflow preventer for one or two-zone irrigation systems. An AVB must be installed on the pipe directly after every control valve, so for systems with more than about six control valves, AVBs are not cost-effective.

AVBs are also the least reliable and least often recommended. Most large cities and suburbs do not allow the use of atmospheric vacuum breakers in lawn sprinkler systems. AVBs cannot be used where they would be subjected to constant pressure, where shutoff valves would be located downstream, where there is a potential for backpressure, or on any system that incorporates chemigation techniques.


Atmospheric Vacuum Breaker Assemblies:

  • Must be installed at least six inches above the highest outlet In the zone
  • Must be installed vertically with the bonnet on top, prevents back-siphonage only
  • Requires one unit per zone installed downstream from zone control valves
  • Not usable where it will be under continuous pressure for more than 12 hours at a time
  • Not usable with chemigation
  • May not be installed where the potential for backpressure is present