Febco 767FR Freeze Resistant PVB Backflow Preventer 1-1/2" FPT | 767FR-150

In stock
SKU
767FR-150
Free Shipping on Orders over $149
Sale Price $392.82
Our Price $1,006.00
You Save 61%

Febco 767FR 1-1/2" in. Freeze Resistant PVB Backflow Preventer

Series 767FR Freeze-Resistant Pressure Vacuum Breakers are designed to prevent backsiphonage of contaminated water under continuous pressure into the potable water supply. Its superior design protects the valve body and internal components during sudden freeze conditions. Water inside the PVB freezes from the outside-inward. As the ice forms and expands causing a buildup of pressure, the 767FR relieves the pressure through a unique relief valve built into the plastic float. Test cocks are positioned at the lowest point of the valve for winterization draining. They feature a bronze body. Maximum Working Pressure: 150 PSI (10.3 bar).

  • Unique built-in relief valve relieves pressure caused by ice formation
  • Replaceable plastic seat
  • Easy maintenance of internal parts
  • O-ring bonnet seal for less possibility of fouling
  • Silicone seat disc for durability
  • Test cocks positioned for easy testing and winterization
  • Compact space saving design
  • Standardly equipped with tee handle quarter turn ball valve shutoffs 1/2" in. - 1" in. (15 - 25mm). The 1-1/4" in. - 2" in. (32 - 50mm) feature lever handles
  • No special tools required for servicing
  • Bronze body for durability

Specifications

A pressure anti-siphon vacuum breaker shall be installed where indicated on the plans to prevent the backsiphonage of contaminated water. This assembly is not to be used where there is a possibility that a backpressure condition may develop. The assembly will incorporate an acetal bonnet with silicone rubber O-ring seal and silicone rubber seat disc. The valve shall have replaceable seats. Check assembly shall be guided over its full stroke by 'V' notch guides. The assembly shall include an internal, built-in relief valve designed to protect the internal components and the backflow body from freezing. The relief valve shall be repeatable, automatically re-seating when the pressure within the valve is below the set point of the freeze relief valve. The assembly shall meet the requirements of ANSI/ASSE Standard 1020. The valve shall be a FEBCO Series 767FR.

Materials

  • Springs: Stainless Steel
  • Bonnet: Celcon
  • Vent Disc: Silicone Rubber
  • Disc Holder Float: Polypropylene
  • Check Valve Disc: Silicone Rubber
  • Check Valve Seat: Noryl Plastic
  • Body: Bronze
  • Celcon is a registered trademark of Celanese Limited.

Pressure - Temperature

Temperature Range: 33° F to 140° (0.5°C to 60°C) Maximum Working Pressure: 150 PSI (10.3 bar) Minimum Working Pressure: 15 PSI (103 kPa)

Capacity

As compiled from documented Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California lab tests.

*Typical maximum flow rate (7.5 feet/sec.)

FEBCO 767 Pressure Vacuum Breaker Capacity

Approvals

FEBCO 767 Pressure Vacuum Breaker Approvals

Approved by the foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California, Manual Section 10.

Typical Installation

This valve is designed for installation in a continuous pressure potable water supply system 12" in. above the highest point of the downstream piping. The valve must be installed with the supply connected to the bottom and in a vertical position. Allow adequate space for periodic inspection, servicing or testing. The valve should not be installed in an area where freezing or spillage will cause damage. Adequate drainage/freeze protection must be provided in cold weather applications.

Important Note: 1.5 PSI (.10 bar) must be exerted against the float spring to seal the float and air inlet. Do not undersize supply and discharge piping.

Important Note: Vacuum breakers are not designed, tested or approved to protect against backpressure backflow or water hammer shock. For protection against backpressure backflow, install FEBCO 825Y/828Y Reduced Pressure Zone Backflow Preventer. For Protection against water hammer shock install a FEBCO Series SA-1 Water Hammer Arrestor utilizing good plumbing practice.

Freeze Protection Guidelines

  • Close main shutoff valve
  • Open upstream drain, test cocks and isolation ball valves to depressurize line
  • Purge with air
  • Leave test cocks and isolation ball valve handles in 45° angle to drain ball valves and prevent casting damage
  • Dimensions for 1-1/2" in. Freeze-Resistant PVB
Brand:
Febco
Weight:
13.0000
Backflow Size:
1-1/2"
Lead Free:
Not Lead Free
End Connection:
FPT
Size (in.):
1-1/2"
Connection:
FPT
Lead Free:
Not Lead Free
Max Working Pressure:
150 PSI
Temperature Range:
32F to 140F
Type:
Pressure Vacuum Breaker (PVB)
Warranty:
1 Year
Test Cocks:
2 FEMALE
Springs:
Stainless Steel
Hydrostatic Test Pressure:
300 PSI
Main Valve Body Materials:
Bronze
Advance Features:
Freeze Resistant
Elastomers:
Nitrile
There are no reviews for this item. Write Review
Start typing your question and we'll check if it was already asked and answered. Learn More
Browse 1 question Browse 1 question
I am installing a 600 gallon above ground water tank in Maine to collect rainwater from my roof. Can I use this valve at the bottom of the tank? I do not want to drain the tank in the winter, and I do not want the drain valve to be damaged by freezing.
maineiac on Oct 27, 2013